Data center energy saving and consumption reduction 36 meters: 22-36
22-28 Meter: Green Energy and Power Supply and Distribution System
22. Reduce UPS energy consumption: choose high-efficiency, modular UPS, and intelligent UPS. Use the UPS ECO mode (intelligent dormancy) to make the UPS run in an economical state.
23. Harmonics not only increases energy consumption but also causes many electrical system failures. Harmonic control: add an isolation transformer; suppress harmonics, add 11 filters to 12 pulses; choose high-quality high-frequency machines or power frequency machines; do a good job of grounding.
24. Perform reactive power compensation to the power system to improve energy utilization efficiency and system stability.
25. Install a power saver at the circuit breaker of the power distribution cabinet and the output end of the UPS.
26. Mains direct supply and high-voltage DC power supply systems can reduce components on the power supply and distribution link and reduce energy waste.
27. The data center uses a variety of energy sources: solar energy, geothermal energy, nuclear energy, tidal energy, wind energy, and biogas energy to reduce the consumption of petrochemical energy and reduce carbon emissions.
28. Vigorously promote the gas-fired combined cooling, heating, and power supply system in which energy can be recycled.
29-33 Gauge: IT Systems
29. Actively adopt cloud computing, share computing resources, and provide elastic resources; reduce excessive data backup work; shut down unused IT loads; identify and eliminate unused or low-utilization equipment and "zombie" applications.
30. Actively select IT equipment with low energy consumption; resolutely eliminate old equipment with high energy consumption.
31. Actively adopt high-temperature resistant servers; actively try to adopt liquid-cooled servers.
32. Add blind plates to the cabinets, effectively use the blind plates to close the cabinets, and reduce the mixing of hot and cold air.
33. The cabinet door has a hexagonal mesh design, and the ventilation rate must be greater than or equal to 78%. For self-owned machine rooms, doorless cabinets can be considered to reduce wind resistance, increase ventilation efficiency, and ultimately save energy consumption.
34-36 Meters: Lighting and Cleaning
34. Choose energy-saving lamps and introduce intelligent lighting systems to improve automation and reduce unnecessary light intensity.
35. Adopt data center micro-module technology. Refrigeration, power supply, computing, fire protection, monitoring, etc. are integrated in one micro-module to reduce energy consumption and isolate faults.
36. Regular dust removal: dust removal for air conditioners, fans, especially fans, filters, and motherboards. Excessive dust leads to increased energy consumption and increased risk of short circuits.